Public Works


SUDAS Design Manual

Cedar Rapids General Supplement to SUDAS Design Manual

SUDAS Standard Specifications

Cedar Rapids Supplemental Specifications to SUDAS Standard Specifications


CR-4910 Pipe Bursting

CR-5010 Pipe and Fittings

Figures:

 SUDAS WM 101 (5010.101) Thrust Blocks   PDF  DWG  
 CR 5010.102 Tracer System  PDF  DWG 
 CR 5010.901  Minimum Clearance Between Water Service and Structure  PDF  DWG 
 CR 5010.990  Restraining Methods  PDF  DWG 
 CR 5010.991 Restraining Rod Requirements  PDF  DWG 
 CR 5010.992 Water Stop Box in Pavement  PDF  DWG 

 

CR-5020 Valves, Fire Hydrants, and Appurtenances

Figures:
CR 5020.991 Temporary Dead End Water Mains
CR 5020.992 Concrete Blocking for Fixtures
CR 5020.993 Hydrant Set Detail (6 sheets)
CR 5020.994 Round Way Connection Main
CR 5010.995 Valve Box Installation < 10 ft. Deep
CR 5010.996 Air Release Detail (2 sheets)
CR 5010.997 Blow Off Detail
CR 5010.998  Typical Residential Service Line (3 sheets)

CR-5030 Testing and Disinfection

CR-5910 Cathodic Protection

Figures:
CR 5910.101 Single Horizontal Anode Installation
CR 5910.102 Single Vertical Anode Installation
CR 5910.103 Continuity Bonding Across Ductile Iron Pipe Joint
CR 5910.104 Continuity Bonding Across Vertical Gate Valve
CR 5910.105 Continuity Bonding Across Butterfly Valve or Horizontal Gate Valve
CR 5010.106 Insulated Rubber & Tape Butt Splice – Sacrificial Anode Cable Connections
CR 5010.107 Insulated Rubber & Tape Wye Splice – Sacrificial Anode Cable Connections
CR 5910.108 Exothermic Weld Procedure for Ferrous Pipe Material (Horizontal Only)
CR 5910.109 Anode Test Station Installation (Red Cap)
CR 5910.110 Anode Test Station – Terminal Board Connection Details
CR 5910.111 Casing Test Station Installation (Blue Cap)
CR 5910.112 Casting Test Station – Terminal Board Connection Details
CR 5910.113 Potential Test Station Installation (Green Cap)
CR 5910.114 Potential Test Station – Terminal Board Connection Details
CR 5910.115 Foreign Crossing (over watermain) Test Station Installation (White Cap)
CR 5910.116 Foreign Crossing (under watermain ) Test Station Installation (White Cap)
CR 5910.117 Foreign Test Station – Terminal Board Connection Details
CR 5910.118 Isolation Test Station (Orange Cap)
CR 5910.119 Isolation Test Station – Terminal Board Connection Details
CR 5910.120 Isolation Test Station installation at Tapping Sleeve (Orange Cap)
CR 5910.121 Flush-Mounted Enclosure for Test Station Terminal Board & Wires
CR 5910.122 Post Type Test Station for Terminal Board & Wires
CR 5910.123 Electrical Continuity Test Procedure for Cable-Bonded Pipe Joints
CR 5910.124 Flange Isolation Kit- Sizing Data for Manufacturer’s Fabrication
CR 5910.125 PVC Pipe Insert for Pipe Diameter from 4” – 24”
CR 5910.126 HDPE Pipe Insert for Pipe Diameter up to 30 “
CR 5910.127 Isolation (Ball Type) Corporation Stop
CR 5910.128 Isolation Service Fitting (Copper Flare) for ¾“ to 2” Pipe
CR 5910.129 Electrical Isolation Devices for Metallic Casing Sleeves
CR 5910.130 Electrical Isolation at Pipe Entry with Reinforced Concrete Wall

CR-7910 Decorative Brick Pavers

CR-8010 Traffic Signals

Figures:
CR 8010.102 Traffic Signal Pole Foundation
SUDAS 8010.104 Inductive Loop Vehicle Detectors
CR 8010.102 Mast Arm Pole Details
SUDAS 8010.107 Wood Post Span Assembly
CR 8010.990 Cabinet Footing Details
CR 8010.991 Precast Handhole Details
CR 8010.992 Push Button Pedestrian Pole and Placement Details
CR 8010.993 Video Detector Mounting Detail

CR-8940 Traffic Signs and Posts

CR-9935 Protection of Trees

Figures:
CR 9935.101 Tree Protection Fencing
CR 9935.102 Utility Bore and Trench in Tree Root Zone

© 2024  Cedar Rapids, Iowa, 101 First Street SE

Powered By Revize Login